Axio Observer 7 materials
Inverted microscope Axio Observer 7 materials
Item no.: 491914-0010-000 (individual configuration)Inverted microscope Axio Observer 7 materials for reflected-light brightfield, darkfield, circular d...
Inverted microscope Axio Observer 7 materials
Item Number: 491914-0010-000 (individual configuration) Reset configurationTip
Current configuration
-
Z-drive operation, flat; right
Item no.: 430051-0000-000Z-drive operation, flat; right
Item Number: 430051-0000-000Z-drive operation, flat; right Flat, ergonomic control knob on the right side, recommended for combinations with mechanical stage or object guides, right
-
Microscope stand Axio Observer 7 materials
Item no.: 431009-9904-000Microscope stand Axio Observer 7 materials
Item Number: 431009-9904-000Microscope stand Axio Observer 7 materials - 6-position objective nosepiece, HD DIC M27 mot. ACR - motorized focus drive (min. step width 10 nm) - prepared for motorized beam path deflection - TFT touchscreen - 1x tube lens to fit with optional available 1-position tube lens mount or 3-position optovar turret mot. - keys for switching TL/RL illumination - circular operation key unit right and left - light- and contrast manager - slider mount 6x30 for Polarizer slider, 90° rotatable - slider mount 6x20 for sliders C-DIC and TIC - interfaces 4x CAN, 2x USB-A, 1x USB-C and TCP/IP - trigger socket (In/Out) for shutter - connecting socket for external UNIBLITZ shutter - external power supply 12V DC 100W, stabilized, 100V-240VAC / 50-60Hz / max. 190VA - USB cable and country-specific line cable
-
3-position Optovar turret mot.
Item no.: 431013-0000-0003-position Optovar turret mot.
Item Number: 431013-0000-0003-position Optovar turret mot.
-
Sideport 60N L, 3 switching positions
Item no.: 425152-0000-000Sideport 60N L, 3 switching positions
Item Number: 425152-0000-000Sideport 60N L, 3 switching positions (100% vis : 0% L / 0% vis : 100% L / 50% vis : 50% L)
-
Path deflection to the tube
Item no.: 000000-1069-227Path deflection to the tube
Item Number: 000000-1069-227Path deflection to the tube for visual observation
-
3-position filter slider, d=25 mm
Item no.: 000000-1062-2593-position filter slider, d=25 mm
Item Number: 000000-1062-2593-position filter slider, d=25 mm for FL incident-light equipment for Axiovert 200
-
6-position reflector turret mot. for P&C modules
Item no.: 424947-0000-0006-position reflector turret mot. for P&C modules
Item Number: 424947-0000-0006-position reflector turret mot. for P&C modules reflector modules exchangable without removal of reflector turret
-
Reflected-light illuminator HD Pol FL mot.
Item no.: 423608-9011-000Reflected-light illuminator HD Pol FL mot.
Item Number: 423608-9011-000Reflected-light illuminator HD Pol FL mot. - slider mounts for manual or motorized stop sliders - slider mount 6x30 for polarizer slider, 90° rotatable - slider mount for 3-position filter slider, dia. 25 mm - beam path apochromatic corrected - transmission from 375 to 825 nm >80%
-
Iris stop slider mot. for incident-light equipment
Item no.: 423646-0000-000Iris stop slider mot. for incident-light equipment
Item Number: 423646-0000-000Iris stop slider mot. for incident-light equipment centerable, can be used as luminous-field diaphragm and/or aperture diaphragm slider (Köhler-type illumination in incident-light beam path)
-
Aperture diaphragm slider MAT mot.
Item no.: 423644-0000-000Aperture diaphragm slider MAT mot.
Item Number: 423644-0000-000Aperture diaphragm slider MAT mot. with integrated ground glass plate
-
Reflector module C-DIC/TIC ACR P&C for reflected light
Item no.: 424941-9000-000Reflector module C-DIC/TIC ACR P&C for reflected light
Item Number: 424941-9000-000Reflector module C-DIC/TIC ACR P&C for reflected light optimized for circular DIC in reflected light, for use with C-DIC/ TIC sliders 6x20, not suitable for polarization
-
Reflector module DIC/Pol ACR P&C shift free for reflected light
Item no.: 424939-9000-000Reflector module DIC/Pol ACR P&C shift free for reflected light
Item Number: 424939-9000-000Reflector module DIC/Pol ACR P&C shift free for reflected light suitable for DIC and polarization in reflected light, consisting of two Pol filters that are firmly oriented towards each other
-
Reflector module dark field ACR P&C for reflected light
Item no.: 424922-9901-000Reflector module dark field ACR P&C for reflected light
Item Number: 424922-9901-000Reflector module dark field ACR P&C for reflected light
-
Reflector module bright field ACR P&C for reflected light
Item no.: 424928-9901-000Reflector module bright field ACR P&C for reflected light
Item Number: 424928-9901-000Reflector module bright field ACR P&C for reflected light
-
Illuminator microLED 3
Item no.: 423053-9074-000Illuminator microLED 3
Item Number: 423053-9074-000Illuminator microLED 3 for mounting on the lamp interface for transmitted-light or reflected-light illumination - colour temperature 5700 K - colour rendering index >90
-
C-DIC slider 6x20 for EC EPN 50x-100x/LD EC EPN 100x
Item no.: 000000-1105-193C-DIC slider 6x20 for EC EPN 50x-100x/LD EC EPN 100x
Item Number: 000000-1105-193C-DIC slider 6x20 for EC EPN 50x-100x/LD EC EPN 100x with rotary slide-in DIC prism
-
C-DIC slider 6x20 for EC EPN 5x-20x/LD EC EPN 20x-50x/EC EP 5x-100x
Item no.: 000000-1105-192C-DIC slider 6x20 for EC EPN 5x-20x/LD EC EPN 20x-50x/EC EP 5x-100x
Item Number: 000000-1105-192C-DIC slider 6x20 for EC EPN 5x-20x/LD EC EPN 20x-50x/EC EP 5x-100x with rotary slide-in DIC prism
-
Mechanical stage 130x85 R/L
Item no.: 432016-9902-000Mechanical stage 130x85 R/L
Item Number: 432016-9902-000Mechanical stage 130x85 R/L for mounting frames K 160 x 110 mm and Z-PIEZO, compatible with objectives autocorr
-
Mounting frame K for reflected light, d=72mm
Item no.: 451344-0000-000Mounting frame K for reflected light, d=72mm
Item Number: 451344-0000-000Mounting frame K for reflected light, d=72mm frame size 160 x 110 mm
-
Stage insert, metal; D=72 mm, d=23 mm
Item no.: 451328-9000-000Stage insert, metal; D=72 mm, d=23 mm
Item Number: 451328-9000-000Stage insert, metal; D=72 mm, d=23 mm
-
Binocular tube 45°/23
Item no.: 425537-0000-000Binocular tube 45°/23
Item Number: 425537-0000-000Binocular tube 45°/23 with manual shutter
-
Conversion filter 5700-3200 K, d=25 mm
Item no.: 427809-9010-000Conversion filter 5700-3200 K, d=25 mm
Item Number: 427809-9010-000Conversion filter 5700-3200 K, d=25 mm for adapting the LED light to the color impression of halogen light
-
Grey filter 0.25, d=25x2
Item no.: 447836-0000-000Grey filter 0.25, d=25x2
Item Number: 447836-0000-000Grey filter 0.25, d=25x2
-
Eyepiece PL 10x/23 Br. foc.
Item no.: 444036-9000-000Eyepiece PL 10x/23 Br. foc.
Item Number: 444036-9000-000Eyepiece PL 10x/23 Br. foc.
-
Eyepiece eyecup
Item no.: 444801-0000-000Eyepiece eyecup
Item Number: 444801-0000-000Eyepiece eyecup
-
Objective EC Epiplan-Neofluar 50x/0.8 BD DIC M27
Item no.: 422372-9961-000Objective EC Epiplan-Neofluar 50x/0.8 BD DIC M27
Item Number: 422372-9961-000Objective EC Epiplan-Neofluar 50x/0.8 BD DIC M27 (FWD=0.59mm)
-
Objective EC Epiplan-Neofluar 100x/0.9 BD DIC M27
Item no.: 422392-9961-000Objective EC Epiplan-Neofluar 100x/0.9 BD DIC M27
Item Number: 422392-9961-000Objective EC Epiplan-Neofluar 100x/0.9 BD DIC M27 (FWD=1.0mm)
-
Objective EC Epiplan-Neofluar 20x/0.50 BD DIC M27
Item no.: 000000-1156-524Objective EC Epiplan-Neofluar 20x/0.50 BD DIC M27
Item Number: 000000-1156-524Objective EC Epiplan-Neofluar 20x/0.50 BD DIC M27 (FWD=2.2mm)
-
Objective EC Epiplan-Neofluar 10x/0.25 BD DIC M27
Item no.: 422342-9960-000Objective EC Epiplan-Neofluar 10x/0.25 BD DIC M27
Item Number: 422342-9960-000Objective EC Epiplan-Neofluar 10x/0.25 BD DIC M27 (FWD=9.0mm)
-
Objective EC Epiplan-Neofluar 5x/0.13 BD DIC M27
Item no.: 000000-1156-514Objective EC Epiplan-Neofluar 5x/0.13 BD DIC M27
Item Number: 000000-1156-514Objective EC Epiplan-Neofluar 5x/0.13 BD DIC M27 (FWD=14.5mm)
-
Dust cover L600xW420xH620 mm
Item no.: 459330-0000-000Dust cover L600xW420xH620 mm
Item Number: 459330-0000-000Dust cover L600xW420xH620 mm for Axio Observer / Axiovert 200/200M
Inverted microscope Axio Observer 7 materials for reflected-light brightfield, darkfield, circular differential interference contrast and polarization; with reflected-light illuminator HD Pol FL mot., 6-position reflector turret mot., objectives EC Epiplan-Neofluar HD DIC and illuminator microLED