Home
Filter Assistant
Overview of filter sets
Filter Set 46
Filter Assistant
Filter Set
Filter Set 46
Item Number 000000-1196-681
Important Note
Additional components can affect the efficiency. Please also note that the illustration is average.
Filter Set
Excitation
Beamsplitter
Emission
67 possible dyes found
------
5-(and-6)-Carboxy-2', 7'-dichlorofluorescein pH 9.0
5-FAM pH 9.0
6-Carboxyrhodamine 6G pH 7.0
6-Carboxyrhodamine 6G, hydrochloride
Alexa 488
Alexa Fluor 488 antibody conjugate pH 8.0
Alexa Fluor 488 hydrazide-water
BCECF pH 5.5
BCECF pH 9.0
BODIPY FL conjugate
Calcein
Calcein pH 9.0
Calcium Green
Calcium Green-1 Ca2+
CFDA
CI-NERF pH 2.5
CI-NERF pH 6.0
Citrine
CyQUANT GR-DNA
DM-NERF pH 4.0
DM-NERF pH 7.0
DTAF
DyLight 488
eGFP (Enhanced Green Fluorescent Protein)
eYFP (Enhanced Yellow Fluorescent Protein)
FDA
FITC
FITC antibody conjugate pH 8.0
FlAsH
Fluo-3
Fluo-3 Ca2+
Fluo-4
Fluorescein
Fluorescein 0.1 M NaOH
Fluorescein antibody conjugate pH 8.0
Fluorescein dextran pH 8.0
Fluorescein pH 9.0
Fluoro-Emerald
FM 1-43
FM 1-43 lipid
GFP (S65T)
Magnesium Green
Magnesium Green Mg2+
mHoneydew
MitoTracker Green
MitoTracker Green FM, MeOH
mNeonGreen
NeuroTrace 500/525, green fluorescent Nissl stain-RNA
Nissl
Oregon Green 488
Oregon Green 488 antibody conjugate pH 8.0
Oregon Green 514
Oregon Green 514 antibody conjugate pH 8.0
PicoGreen dsDNA quantitation reagent
Rhodamine 110
Rhodamine 110 pH 7.0
Rhodamine 123, MeOH
Rhodamine Green
Rhodaminen Green pH 7.0
Rhodol Green antibody conjugate pH 8.0
Sodium Green Na+
SYBR Green I
SYTO 13-DNA
TO-PRO-1-DNA
TOTO-1-DNA
YO-PRO-1-DNA
YOYO-1-DNA
Please note that the given values are typical only and not guaranteed.
Show total efficiency
Update
67 possible dyes found
Fluorescent dyes
Excitation
Emission
No dyes were found.
5-(and-6)-Carboxy-2', 7'-dichlorofluorescein pH 9.0
504 nm
525 nm
5-FAM pH 9.0
492 nm
518 nm
6-Carboxyrhodamine 6G pH 7.0
526 nm
547 nm
6-Carboxyrhodamine 6G, hydrochloride
525 nm
547 nm
Alexa 488
493 nm
520 nm
Alexa Fluor 488 antibody conjugate pH 8.0
499 nm
520 nm
Alexa Fluor 488 hydrazide-water
493 nm
518 nm
BCECF pH 5.5
485 nm
521 nm
BCECF pH 9.0
501 nm
527 nm
BODIPY FL conjugate
503 nm
512 nm
Calcein
493 nm
514 nm
Calcein pH 9.0
494 nm
514 nm
Calcium Green
506 nm
530 nm
Calcium Green-1 Ca2+
506 nm
529 nm
CFDA
495 nm
517 nm
CI-NERF pH 2.5
504 nm
541 nm
CI-NERF pH 6.0
513 nm
538 nm
Citrine
515 nm
530 nm
CyQUANT GR-DNA
502 nm
523 nm
DM-NERF pH 4.0
493 nm
530 nm
DM-NERF pH 7.0
509 nm
537 nm
DTAF
495 nm
517 nm
DyLight 488
493 nm
518 nm
eGFP (Enhanced Green Fluorescent Protein)
488 nm
509 nm
eYFP (Enhanced Yellow Fluorescent Protein)
514 nm
526 nm
FDA
495 nm
517 nm
FITC
495 nm
517 nm
FITC antibody conjugate pH 8.0
495 nm
519 nm
FlAsH
509 nm
529 nm
Fluo-3
506 nm
527 nm
Fluo-3 Ca2+
506 nm
527 nm
Fluo-4
494 nm
516 nm
Fluorescein
495 nm
517 nm
Fluorescein 0.1 M NaOH
493 nm
513 nm
Fluorescein antibody conjugate pH 8.0
493 nm
517 nm
Fluorescein dextran pH 8.0
501 nm
524 nm
Fluorescein pH 9.0
490 nm
514 nm
Fluoro-Emerald
495 nm
524 nm
FM 1-43
472 nm
578 nm
FM 1-43 lipid
473 nm
579 nm
GFP (S65T)
489 nm
509 nm
Magnesium Green
507 nm
530 nm
Magnesium Green Mg2+
507 nm
531 nm
mHoneydew
478 nm
562 nm
MitoTracker Green
490 nm
512 nm
MitoTracker Green FM, MeOH
490 nm
512 nm
mNeonGreen
506 nm
517 nm
NeuroTrace 500/525, green fluorescent Nissl stain-RNA
497 nm
524 nm
Nissl
497 nm
524 nm
Oregon Green 488
498 nm
526 nm
Oregon Green 488 antibody conjugate pH 8.0
498 nm
526 nm
Oregon Green 514
512 nm
532 nm
Oregon Green 514 antibody conjugate pH 8.0
513 nm
533 nm
PicoGreen dsDNA quantitation reagent
502 nm
522 nm
Rhodamine 110
497 nm
520 nm
Rhodamine 110 pH 7.0
497 nm
520 nm
Rhodamine 123, MeOH
507 nm
529 nm
Rhodamine Green
497 nm
524 nm
Rhodaminen Green pH 7.0
497 nm
523 nm
Rhodol Green antibody conjugate pH 8.0
499 nm
524 nm
Sodium Green Na+
507 nm
531 nm
SYBR Green I
498 nm
522 nm
SYTO 13-DNA
488 nm
506 nm
TO-PRO-1-DNA
515 nm
531 nm
TOTO-1-DNA
514 nm
531 nm
YO-PRO-1-DNA
491 nm
507 nm
YOYO-1-DNA
491 nm
509 nm