Objective LD Plan-Neofluar 40x/0.60 Corr
Objective LD Plan-Neofluar 40x/0.60 Corr
Item no.: 441350-9970-000(no longer available)
Objective LD Plan-Neofluar 40x/0.60 Corr (D=0-1.5mm) (WD=3.3mm at D=0mm and WD=2.5mm at D=1.5mm)
Full DescriptionMagnification | 40x |
Numerical Aperture | 0.6 |
Free Working Distance [mm] | 2.9 at cover glass 0.75 |
Coverglass Thickness [mm] | 0 - 1.5 |
Thread Type | W0.8x1/36" |
Immersion | Without Immersion |
Field of View [mm] | 23 |
Parfocal Length [mm] | 45.06 |
Long Distance | |
Correction Ring | |
Iris | |
Optical System | Infinity Color Corrected System (ICS) |
Color Correction | semi-apochromatic |
Biomedical Applications | |
---|---|
Fluorescence | |
- Multichannel | |
- Ultraviolet Transmission | |
- Infra Red Transmission | |
BrightField | |
DIC [Differential Interference Contrast] | |
High Contrast DIC | |
PlasDIC | |
Phase Contrast | |
VAREL Contrast | |
Hoffman Modulation Contrast | |
Polarization Contrast | |
Materials (Reflected Light) Applications | |
BrightField | |
BrightField/DarkField | |
Reflected Light DIC | |
High Contrast DIC | |
DIC with circular polarized light | |
Total Interference Contrast | |
Polarization Contrast | |
Options | |
Definite Focus.2 | |
Confocal Microscopy | |
- Ultra Violet | |
- VIS (visible light) | |
- NLO-IR / 2 Photon | |
Total Internal Reflection Fluorescence | |
Apotome | |
Microdissection |
-
Adapter M 27x0.75 / W 0.8 H "0"
Item no.: 000000-1095-168Adapter M 27x0.75 / W 0.8 H "0"
Item no.: 000000-1095-168Adapter M 27x0.75 / W 0.8 H "0"
-
DIC slider LD PN 40x/0.60 II
Item no.: 426955-0000-000DIC slider LD PN 40x/0.60 II
Item no.: 426955-0000-000DIC slider LD PN 40x/0.60 II
-
PlasDIC slider for LD PN 40x/0.60 corr
Item no.: 444505-0000-000PlasDIC slider for LD PN 40x/0.60 corr
Item no.: 444505-0000-000PlasDIC slider for LD PN 40x/0.60 corr
Note:
All measures in [mm]
mech. Arbeitsabstand = mechanical working distance
Deckglas = cover glass
Objektebene = object plane
Objektfeld = object field
Ausleuchtung = illumination
Probenzugänglichkeit = specimen accessibility
Note:
Please note that due to production tolerances, the given values are typical only and not guaranteed.
The version of the EC Plan-Neofluar objectives with extra long working distance to be used at the inverted research microscope Axiovert 200. Beside the well-known, fluorescence of all EC Plan-Neofluar objectives the LD versions have a correction collar to adjust the objective to different cover glass thicknesses from 0 to 1.5 mm. They can of course be used in all known contrast techniques such as Brightfield, Phase contrast, DIC and PlasDIC.
Objective LD Plan-Neofluar 40x/0.60 Corr (D=0-1.5mm) (WD=3.3mm at D=0mm and WD=2.5mm at D=1.5mm)